Wavecrest DTS2077-02 Timing Analyzer OEM Refurbished This is a used unit, in excellent operational condition. This unit is freshly calibrated, 11/06. Calibration is NIST traceable from a certified independent lab and comes with certificate of calibration, test data and dated calibration sticker. Unit comes with User's Manual on CD-ROM. Unit comes as shown, no other accessories are included. Unit comes with a certificate of calibration. All units will have a dated calibration sticker. All sources are traceable to NIST, except where noted. We do not supply NIST numbers in accordance with NCSLI Position Statement 96-1: "test report numbers should not be used nor required as proof of the adequacy or traceability of a test or measurement". NIST, NVLAP and A2LA have concurred with this position. NCSLI also notes that international standards ISO 900X, ISO Guide 25 (ISO/IEC 17025), ISO 10012 and ANSI/NCSL Z540-1 do not require the use or reporting of NIST test report numbers. Manufacturer's Specifications/Features: (Please note that not all features may be included in this item) The stringent timing specifications of today’s data communications devices require a signal integrity analysis solution that outperforms general test instruments. The WAVECREST DTS-2077 is a high-performance Timing Analyzer used for the debug, characterization and production test of high-performance, high frequency devices and circuits. Timing uncertainties such as jitter, propagation delay, frequency modulation and crosstalk can easily be analyzed and tested with the DTS-2077. This capability can be used on either data signals or clock signals. * Frequency Range: 0.4Hz to 1.3GHz * Jitter Noise Floor: < 6ps rms (3ps rms typical at cal frequency) (1) * Jitter Measurement Accuracy: < 2ps (2) * Time Measurement Range: +/-2.5s * Frequency Measurement Accuracy: 1PPM * Time Base Stability (Short Term Aging): 5x10-11 * Input Range: +/-1.1V(50 Ohm load) * VREF Accuracy: +/-(1.5 mV+0.75% of setting) (1) Jitter Noise Floor is the minimum Jitter measurement that can be made. This measurement is an accumulation of several jitter frequency components and their effect on the measurement in question. The Jitter Noise Floor measured in the Frequency domain is less than 1ps. (2) Jitter Measurement Accuracy is a function of the hardware's measurement repeatability. * Automatic Arming - Used for serial data streams and clock signals that repeat indefinitely. This feature is critical in enabling clock-less data signal analysis. * Internal Sampling Oscilloscope - Used for identifying signal characteristics that are present at the channel input. The oscilloscope has an effective sampling rate of 100GHz. * User Programmable Subroutine Memory - Used for developing production and characterization scripts to enhance throughput and measurement time. * Built-In Internal Calibration - Used for self-calibration of internal hardware. External reference ports accessible on back panel for accuracy verification. * Built-In External Calibration - Used for timing and voltage deskew of cables, probes and other interconnect hardware. This unit retailed for over $77,000.00 brand new, and here is your chance to get one at a fraction of the original price! ANOTHER GREAT DEAL FROM TECHRECOVERY! * Test equipment with calibration comes with a 100 day guarantee from defects and 10 day right of return. * At TechRecovery, your complete satisfaction is our goal. If you have any questions, don't hesitate to call us at with questions. |