Ttc acterna fireberd 4000 analyzer options & adaptors

UpUp


Subject: Ttc acterna fireberd 4000 analyzer options & adaptors
ยป Add USTechStore To Your Favorite
TTC Acterna Fireberd 4000 Analyzer Options & Adaptors
TTC Acterna Fireberd 4000 Analyzer Options & Adaptors
The FIREBERD 4000 Communications Analyzer is a flexible, cost-effective instrument that tests digital circuits and equipment. Combining convenience and reliable performance, the FIREBERD 4000 is ideally suited for a wide variety of test applications.
Operating at rates from 50 b/s to 15 Mb/s, the FIREBERD 4000 provides a high degree of flexibility for testing G.703, T-Carrier, and DDS circuits, evaluating equipment performance, or performing long-term or unattended testing. THe instrument features a range of standard data rates, plus the ability to operate at non-standard data rates when the optional frequency synthesize is installed.
Synchronous: 50 b/s to 15 Mb/s.
Asynchronous: 50 b/s to 20 kb/s (Internal RS-232/V.24 and MIL-188C interfaces only).
Clock Sources: Fixed internal frequencies, data interface and external BNC.
Internal Clock Frequencies: 300 Hz, 1.2 kHz, 2.4 kHz, 4.8 kHz, 9.6 kHz, 19.2 kHz, 56 kHz, 64 kHz, 128 kHz, 256 kHz, 512 kHz, 1544 kHz, and 2048 kHz +/- 5ppm.
Fixed Patterns: Mar, Space, 1:1, 1:7, 3-in-24, and a user-programmable pattern of 3 to 24 bits in length.
Pseudorandom Patterns: 63, 511, 2047, 215-1, 220-1, 223-1, QRSS.
Messages: Non Programmable: standard FOX asynchronous message in four different code levels; Programmable: three asynchronous messages up to 2000 bytes in length.
Asynchronous Setup: Odd, none, or even parity; 5- to 8-bit code levels; 1, 1.5, or 2 stop bits.
Error Insertion: Single error or fixed 10-3 rate in generated data only.
Sync Loss Thresholds: User-Selectable 100/1000, 250/1000, and 20,000/100,000 errors/total bits.
Block Lengths: 102 to 106 bits, or pattern lengths.
Frequency Measurement Range: 50 Hz to 16 MHz.
Summary Results (Non-Zero results only): Bit errors, bipolar violations (BPVs), character errors, code errors, cylic redundancy check (CRC) errors, block errors, frame errors, frame alignmen signal (FAS) errors, pattern slips, pattern loss.
Error Results: Average bit error rate, average block error rate, bit errors, bit error rate, blocks, block errors, character errors, pattern loss, pattern slips.
Interface-Specific Results: Average bipolar violation rate, average code error rate, average CRC error rate, average FAS error rate, BPVs, BPV rate, code error rate, code errors, CRC errors, FAS errors, frame errors, one-second CRC error count.
Signal and Time Results: Generator frequency, receive frequency, RTS/CTS delay, error-free seconds, percent error-free seconds, pattern loss seconds, test seconds, errored seconds, time and date.
Front-Panel Program Storage: Store and recall up to 10 sets of front-panel control and auxiliary function settings.
Auxiliary Functions: Over 14 programmable functions provide additional operational control.
Non-Volatile Memory: Stores current front-panel switch settings, 10 front-panel programs, three user-defined messages, and time and date of last power-down.
System Includes Following Adaptors:
QTY 1 x TTC Model 40200 RS449 DTE / DCE Adaptor
QTY 1 x TTC V.35-306 DTE / DCE Interface Adaptor
System is installed with options:
4001 Second Interface Slot
4003 DS1 Jitter Generation
4006 Synchronous Long User Patterns
What you see in the above picture(s) is what you get
Note: As a liquidator, we have no expertise to test thousands of different items that we carry each month. All Sales Come With 30 Days DOA (Dead On Arrival) Warranty Unless Advertised "As-Is". To avoid confusion, please check the item description and look for the Logo in front of the description.
This item has been seen by alt people!