N-1000-4X northern computers card access system

UpUp


Subject: N-1000-4X northern computers card access system
Versatile, reliable and expandable. The three main components delivered with every N-1000 make it the most popular access control panel ever.
A key feature of the N-1000 includes its completely distributed database. All card information, time zone information, relay control information and alarm point information is loaded into the N-1000's memory. The unit will operate completely stand-alone with no dependence on any other equipment.
The most important feature of any access control system is the ability to be expanded. The N-1000 will operate as a stand-alone two or four door controller, and as needs increase up to 31 N-1000's may be connected on an RS-485 dropline (63 using 20mA current loop). Using WIN-PAK access control software, a total system is achieved by having each drop-line connected to a communication port, modem or ethernet terminal server.
The N-1000-IV is designed to operate off-line, making access control decisions independently from a PC or other controlling device. It can also be connected to a host computer for system configuration, alarm monitoring and direct control. Connectivity to the host computer is accomplished via direct serial communication (RS-232 or RS-485), dial-up modem or TCP/IP network connection.
* 4 reader control panel (N-1000-IV)
* 2 reader control panel (N-1000-III)
* Supports all major reader technologies and 16-digit ABA card formats
* Distributed database for independent operation
* Operates in remote site configurations with dial-up (requires M-9600-2 and N-485-HUB-2) or leased lines
* N-1000-IV-X: 25,000 card memory N-1000-IV: 5,000 card memory
* N-1000-IV-X: 6,600 buffers N-1000-IV: 10,200 buffers
* RS-485 and 20 mA communications are jumper selectable
* Compatible with the N-1000-II
* 16 supervised alarm inputs. Separate inputs for tamper switch and primary power fail monitoring
* DPDT Form C relays; 4 on N-1000-III/IV, 8 on N-1000-III/IV-X
* 63 time zones to control card access, relays and alarm points
* Relays are "time-programmable" for automatic control
* 12 VDC, 500 mA output for Reader/IR devices
* 8 programmable card formats supported
* Preassembled, hinged, locking enclosure with battery and toggle switch
* UL294 listing/CE certification
For more infomation visit: http://www.honeywellaccess.com/products/hardwr/27949.html