Ifr fm/am-1200 radio communication service monitor

UpUp


Subject: Ifr fm/am-1200 radio communication service monitor
IFR FM/AM-1200 Radio Communication Service Monitor
*****Guaranteed Working, 30 Day Warranty*****
The FM/AM-1200 is a processor controlled, digitally synthesized FM/AM/SSB receiver and generator, with an integral oscilloscope/spectrum analyzer. The receiver is a triple conversion superheterodyne receiver capable of receiving signals from 250 kHz to 999.9999 MHz. The signal generator is capable of producing modulated or unmodulated RF signals from 250 kHz to 999.9999 MHz. A function generator will produce six functions (Ramp, Triangle, Square, Sine, DTMF and Pulse) with ranges from 10 Hz up to 10 kHz and one function up to 30 kHz. A duplex generator can produce a signal up to +/- 49.99 MHz from the received frequency. The oscilloscope and spectrum analyzer utilize a common CRT. Bandwidth of the oscilloscope is DC to 1 MHz and the dynamic range of the spectrum analyzer is from -30 dBm to -100 dBm.
Receive/Monitor Specifications:
Frequency Range: 250 kHz to 999.9999 MHz in 100 Hz increments.
Sensitivity Level: 2 µV (1 MHz to 1000 MHz, FM narrow).
Output Level: (Into an open circuit)
Input Protection: 0.25 WATT (max. without damage)
Range: 0 to 15 and 0 to 150 WATTS peak or average responding.
Accuracy: 1 to 600 Mhz +/- 7% reading +/- 3% of full scale. 600 to 1000 MHz +/- 20% of reading +/- 3% of full scale.
Input Power: 50 WATTS continuous. 150 WATTS, one minute "ON", five minutes "OFF".
RF Signal Generator Specifications:
Frequency Range: 250 kHz to 999.9999 MHz in 100 Hz increments.
Frequency Accuracy: (See Master Oscillator)
Post Detection: (300 Hz to 3 kHz bandwidth)
RF Output Power: -127 dBm to -20 dBm (10 dB steps with 11 dB range vernier into 50 Ohms).
RF Output Accuracy: +/- 2.5 dB
Variable Generate: When in the "locked" position, the generator is phase-locked to the master oscillator. When switched from the "locked" position, the generator may be varied 10 kHz.
Internal Modulation: (See Function Generator)
FM: 2 Hz to 30 kHz (DC when in variable generate).
AM: 10 Hz to 10 kHz (30% maximum modulation above 5 kHz).
Input Impedance: Greater than 10 K Ohms.
Microphone Input: Generator can be switched on by an external microphone. FM/AM-1200 has internal pre-amp with speech limiting.
Duplex Generator Specifications:
Frequency Range: +/- 49.99 MHz from receive frequency in 10 kHz steps.
Frequency Accuracy: (See Master Oscillator)
Duplex Port: -60 dBm +/- 10 dB fixed level
Input Protection: 0.25 WATT (max. without damage)
Transmission Port: -80 dBm +/- 5 dB fixed level
* Model Cat-6, 6dB attenuator, 50 ohm, DC to 1500 MHz
* Tested by our Lab Technician and in good working condition.