Generac guardian home standby generator 16K 16,000 watt

UpUp


Subject: Generac guardian home standby generator 16K 16,000 watt
This is a NEW Guardian Quiet Source Generator, Model Number 05243. This INCLUDES the Transfer Switch , Electronic Governor, Pre-wired External Connection Box, Flexible Fuel Line, Composite Mounting Pad, and Pre-wired Conduits.
Generac's residential generator system is permanently installed outside your home, similar to a central air conditioner. The generator and its automatic transfer switch are connected to your home's utility service. Within seconds of an outage occurring, the generator starts up and the transfer switch provides electrical power to all pre-selected circuits. Automatically! You chose up to 16 circuits in your home or business to switch over in an outage.
The most powerful air-cooled standby generator currently made and the only air-cooled unit with
Generac's patent pending Quiet-Test feature.
All models are UL 2200 Listed, your only assurance of local building code approval, safety and certified kW ratings.
All air-cooled systems include:
Hinged top and removable front panel for easy serviceability
Natural gas or LP gas operation
Tough composite plastic mounting pad
California Emissions compliance
Generator engines comply with applicable CARB and SCAQMD emissions
requirements for stationary emergency standby generators
Rated Maximum Continuous Power Capacity(LP).....................................16,000 Watts*
Rated Maximum Continuous Power Capacity(NG).....................................15,000Watts*
Rated Voltage...................................................................................................120/240
Rated Maximum Contiuous Load Current 240 Volts.....................................66.6LP/62.5NG
120 Volts.....................................133.3LP/125NG
Main Line Circuit Breaker.................................................................................65 AMP
Phase...................................................................................................................1
Number of Rotor Poles.......................................................................................2
Rated AC Frequency..........................................................................................60Hz
Power Factor.......................................................................................................1
Battery Requirement (not included)....Group 26,12 Volt Neg. Ground &525 Cold-Cranking
Unit Weight.......................................................................................................445 Pounds
Dimensions(L"xW"xH")......................................................................48x24x28-1/4
Sound output in dB(A) at 23ft.w/generator operating at full load.............71.5
Sound output in dB(A) w/generator in Quiet-Test exercise mode............59
Type of Engine...............................................................................GENERAC OHVI V-Twin
Number of Cylinders......................................................................2
Rated Horse Power........................................................................30 @ 3,600 rpm
Displacement...................................................................................992cc
Cylinder Block............................................................................Aluminum w/cast iron sleeve
Valve Arrangement...........................................................................Overhead valve
Ignition System...................................................................................Solid- State w/Magneto
Governor System..............................................................................Electronic
Compression Ratio...........................................................................9.5:1
Starter....................................................................................................12Vdc
Oil Capacity Including Filter..................................................................Approx. 1.7 Qts.
Standby Operating RPM.........................................................................3,600
Exercise RPM.............................................................................................2,400
1/2 Load.....................................................................173
Full Load....................................................................245
Liquid Propane ft3/hr (gal/hr)
1/2 Load.......................................................................59 (1.59)
Full Load......................................................................92(2.51)
Required fuel pressure to generator fuel inlet at all load ranges -5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas
Auto...................................................................Automatic Start on Utility failure 7 day exerciser
Off...........................................Stops unit. Power is removed, Control and charger still operate
Manual/Test (start)................Start w/starter control, unit stays on. If utility fails, transfer to load
Engine Start Sequence......................Cyclic cranking:7 sec. on,7 rest (90 sec. max duration)
Engine Warm-up.....................................10 seconds
Engine Cool -Down...................................1 minute
Starter Lock out.........................Starter can not re-engage until 5 sec. after engine stops
2.5 AMP Timed Trickle Battery Charger.................................................Standard
Automatic Voltage Regulator w/ Overvoltage Protection......................Standard
Automatic Low Oil Pressure Shutdown...................................................Standard
Overspeed Shutdown................................................................................Standard, 72Hz
High Temp. Shutdown................................................................................Standard
Overcrank Protection..................................................................................Standard
Saftey Fuse.................................................................................................Standard
*Maximum wattage and current are subject to and limited by such factors as fuel Btu content, amient temperture, altitude, engine power and condition, ect.
For delivery it is necessary for someone to be there. The delivery driver will call you 24 hours before delivery to make arrangements. Delivery will be between 3-21 days after purchase is complete. If you have any questions about this product please e-mail us at .