This E1 service tester is a multi-functional digital transmission system test device, designed for the installation test, engineering check and acceptance, daily maintenance of the E1 PCM line (G.703 2Mbit/s), mainly performing channel test, alarm analysis, fault finding and signaling analysis of the E1 (2Mb/s) line. This instrument mainly has following functions: · Support interface test of unbalanced 75Ω and balanced 120Ω. · Support HDB3 and AMI line coding. · Framed test under TX/RX mode (Out-of-service test). √ Framed/unframed end-to-end 2Mb/s BER testing. √ N×64Kb/s BER testing. √ Can monitor signal loss , AIS, frame loss, remote alarm, remote multiframe alarm, CRC multiframe loss, CAS multiframe loss, pattern loss alarm and bit, CODE, FAS, E-BIT error and so on. √ Clock slip measurement. · Online BER monitoring and timeslot analysis under RX HI-Z (high impedance) and through (bridge) mode. √ Performance test of bit error, coding error, FAS error, CRC4 error and E bit error. √ FAS and MFAS word analysis, timeslot busy or idle status display. √ Timeslot content monitoring, monitoring and display of 8-bit digital code word in any selected timeslot. √ Any 64kb/s tone channel monitoring. √ CAS (channel associated signaling) ABCD code monitoring and CCS (common channel signaling) TS16 timeslot monitoring. · Framed/unframed Round Trip Delay measurement. · 2M or 64kb/s signal of SDH transmission network automatic protection switching (APS) delay measurement. √ Simulate PCM terminal to perform various error insertion and alarm insertion. √ Transmit editable Si, Sa, A, FAS, CRC-4, MFAS, NMFAS and E- bit. √ Insert idle codes into one or more timeslots, and the idle code pattern is programmable. √ Insert single audio signals whose signal frequency and voltage are adjustable in one or more timeslots. √ Monitor any voice channel in the receiving terminal, single audio channel can measure signal voltage and frequency at the same time. √ CAS (channel associated signaling) ABCD code programming, CCS (common channel signaling) TS16 content programmable; · 2M signal level, frequency, offset measurement. · Transmission clock maximum deviation ±999ppm, effectively assess the clock restoration capability of the tested circuit. · Transmission clock: internal, interface, external 2M clock/signal (optional). · Test code type pattern: pseudorandom binary sequence (PRBS), fixed code and 16BIT user programmable code. · Bit, rate and other types of error insertion modes. · Real time display open circuit and short circuit status of the transmission circuit, effectively identify cable fault. · Has automatic test function at fixed time. · Perform the error analysis according to the G.821, G.826 and M.2100 standard of ITU-T. · Use the TestManager software for measurement result analysis, clean up, archiving and print output on PC via the serial port; · Handheld structure, durable design, suitable for carrying around and on-spot measurements. · High resolution backlight LCD, smart navigation mode operation displays in English. · Combine BERT, time-slot analysis, signalling testing, signal analysis, and other functions together. · Synchronization performance measurements give references to the more and more important system synchronization problem. · Up to 99 days continuance test performance. · Built-in NiMH rechargeable batteries and embedded with smart fast charger circuit. Can be charged with automobile cigarette lighter battery adapter. · Real-time clock and storages could be kept during a long time by power supply of the second spare battery without AC adapter and built-in NiMH battery module. · By using TestManager software, upgrading the embedded software of the instruments via the serial port to perfect the functionalities of the instrument and protect your investment. Automobile Cigarette Lighter Battery Adapter Cable AA NiMH Rechargeable Batteries 75ohm, Unbalanced, 120ohm, balanced; High Input Impedance >2KW Unframed , PCM30, PCM30CRC, PCM31, PCM31CRC Accuracy: ±1Hz, range: -999ppm~+999ppm Generated from inside, interface extract, external 2M clock/ signal (optional) Frequency range: 200Hz~3400Hz Voltage range: -60.00dB~+3.14dB Receiving frequency range: 200Hz~3400Hz Measurement frequency accuracy: ±1Hz Receiving voltage range: -60.00dB~+3.14dB -60.00dB~-21.00dB range: ±2.87dB -20.00dB~+3.14dB range: ±0.21dB You must have a return authorization number to return your product. Please contact to obtain an authorization number, which shall be valid for 14 days after issued. This product is covered by a warranty of 12 months. You must have a return authorization number to service your product. Please contact to obtain an authorization number. |