Supply voltage 200-240 V units 3 x 200/208/220/230/240 V ±10% Supply voltage 380-500 V units 3 x 380/400/415/440/460/500 V ±10% Max imbalance of supply voltage : Displacement Power Factor (cos f) No. of switchings on supply input L1, L2, L3 Rated motor voltage, 200-240 V units Rated motor voltage 380 - 500 V units 380 / 400 / 415 / 440 / 460 / 480 / 500 V Rated motor voltage 525 - 600 V units Number of programmable digital inputs 16, 17, 18, 19, 27, 29, 32, 33 0-24 V DC (PNP positive logics) Reliable galvanic isolation : all digital inputs are galvanically isolated from the supply voltage (PELV). In addition, the digital inputs can be isolated from the other terminals on the control card by connecting an external 24V DC supply and opening switch 4. VLT 5001 - 5250, 525 - 600V do not meet PELV. No. of programmable analogue voltage inputs / thermistor inputs No. of programmable analogue current inputs Reliable galvanic isolation : All analogue inputs are galvanically isolated from the supply voltage (PELV) * as well as other inputs and outputs. *VLT 5001 - 5250, 525-600 V do not meet PELV Control card, pulse / encoder input: No. of programmable pulse encoder inputs Max. frequency on terminals 29, 32, 33 Max. frequency on terminals 29, 32, 33 0-24 V DC (PNP positive logics) Accuracy (100 - 1 kHz), terminals 17, 29, 33 Max. error : 0.5% of full scale Accuracy (1 - 5 kHz), terminal 17 Max. error: 0.1% of full scale Accuracy (1-65 kHz), terminals 29, 33 Max. error : 0.1% of full scale Reliable galvanic isolation : All pulse / encoder inputs are galvanically isolated from the supply voltage (PELV)*). In addition, pulse and encoder inputs can be isolated from the other terminals on the control card by connecting an external 24 V DC supply and opening switch 4. * VLT 5001-5250, 525-600 V do not meet PELV. Control Card, digital / pulse and analogue outputs: No. of programmable digital and analogue outputs. Voltage level at digital / pulse output Minimum load to ground (terminal 39) at digital pulse output Frequency ranges (digital output used as pulse output) Current range at analogue output Maximum load to ground (terminal 39) at analgoue output Max. error : 1.5% of full scale Reliable galvanic isolation : all digital and analogue outputs are galvanically isolated from the supply voltage (PELV)*, as well as other inputs and outputs. * VLT 5001-5250, 525 - 600 V do not meet PELV. Max. load (short circuit protection) Reliable galvanic isolation : The 24 V DC supply is galvanically isolated from the supply voltage (PELV)*, but has the same potential as the analogue outputs.* Control card, RS 485 serial communication Reliable galvanic isolation : full galvanic isolation No. of programmable relay outputs Max. terminal load (AC) on 4-5, control card Max. terminal load (DC) on 4-5, control card Max. terminal load (DC) on 4-5, control card for UL / cUL applications Max. terminal load (AC) on 1-3, 1-2, power card Max. terminal load on 1-3, 1-2 , power card Min terminal load on 1-3, 1-2, power card Brake Resistor terminals (only SB, EB, DE and PB units): 24 V DC ±15% (max. 37 V DC for 10 sec) 15 W - 50 W (50 W for start-up, 20 msec.) Reliable galvanic isolation : full galvanic isolation if the external 24 V DC supply is also of the PELV type. Cable lengths, cross-sections and connectors Max. motor cable length, screened cable Max. motor cable length, unscreened cable Max. motor cable length, screened cable VLT 5011 380 - 500 V Max. motor cable length, screened cable VLT 5011 525 - 600 V and VLT 5008, normal overload mode, 525 - 600 V Max. brake cable length, screened cable Max. loadsharing cable length screened cable 25m from frequency converter to DC bar. Max. cable cross-section for 24 V external DC supply - VLT 5001 - 5027, 200 - 240 V; VLT 5001 - 5102 380-500 V; VLT 5001-5062 525-600V VLT 5032-5052 200-240 V; VLT 5122-5500 380-500 V; VLT 5075-5250 525-600 V Max. cross-section for control cables Max. cross-section for serial communication If UL / cUL is to be complied with, cable with temperature class 60/75oC must be used (VLT 5001 - 5062 380 - 500 V, 525 - 600 V and VLT 5001 - 5027 200 - 240 V). If UL / cUL is to be complied with, cable with temperature class 75oC must be used (VLT 5072 - 5500 380 - 500 V, VLT 5032 - 5052 200 - 240 V, VLT 5075 - 5250 525 - 600 V). Connectors are for use of both copper and aluminium cables, unless other is specified. |