Dental equipment-autoclave/ sterilizer midmark M9

UpUp


Subject: Dental equipment-autoclave/ sterilizer midmark M9
NEW IN THE BOX M9 MIDMARK AUTOCLAVE WITH AUTOMATIC DOOR,MANY MODELS AVAILABLE. WE ARE A FACTORY CERTIFIED DEALER FOR MIDMARK"30 YRS" FULL SERVICE REPAIR FACILITY!
1 BIOLOGICAL SPORE TEST KIT WITH EVERY AUTOCLAVE SOLD!
The Global Autoclave Monitoring System
Global Autoclave Compliance is a widely recognized industry leader. Our clients include leading medical, dental and related health care practices committed to infection control and patient safety. We monitor and document autoclave sterilization effectiveness through biological spore testing. Biological spore testing is the only compliant testing method approved by the CDC, State Health Department and Autoclave Manufacturers. Our spore test monitoring program is convenient, comprehensive, and in many states… "It’s the Law". Weekly, Monthly, Bi-monthly and Quarterly contracts are available.
2 ) Spore Population and Quality
The Biological indicators used by Global Autoclave Compliance provide the best assurance of sterilization, by challenging the sterilizer with a highly resistant spore in a quantifiably denser population . We only trust the world wide leader 3M to manufacture our Biological Indicators, bringing you unparalleled quality!
The unique ampoule design provides a challenge to steam penetration similar to that which would be encountered in restricted areas of instruments. The self contained design also greatly reduces the potential for sample contamination. This more challenging test varies greatly from the old glassine envelope used by other third party labs.
National Monitoring Guidelines - Dental Practices
Centers for Disease Control and Prevention (CDC)
Guidelines for Infection Control in Dental Health-Care Settings - 2003MMWR December 19, 2003 / 52(RR17); 1-61
1. Use mechanical, chemical, and biological monitors according to the manufacturer's instructions to ensure the effectiveness of the sterilization process (IB) (248,278,279).
2. Monitor each load with mechanical (e.g., time, temperature, and pressure) and chemical indicators (II) (243,248).
3. Place a chemical indicator on the inside of each package. If the internal indicator is not visible from the outside, also place an exterior chemical indicator on the package (II) (243,254,257).
4. Place items/packages correctly and loosely into the sterilizer so as not to impede penetration of the sterilant (IB) (243).
5. Do not use instrument packs if mechanical or chemical indicators indicate inadequate processing (IB) (243,247,248).
6. Monitor sterilizers at least weekly by using a biological indicator with a matching control (i.e., biological indicator and control from same lot number) (IB) (2,9,243,247,278,279).
7. Use a biological indicator for every sterilizer load that contains an implantable device. Verify results before using the implantable device, whenever possible (IB) (243,248).
American Dental Association (ADA)
Monitor sterilizers at least weekly with biological (spore) indicators.1 Check whether your state dental board has different requirements.
Consider using biological (spore) indicators daily if the sterilizer is used frequently (e.g., several loads per day). Daily monitoring allows for earlier discovery of equipment malfunctions or procedural errors.
A positive spore test result indicates that sterilization was incomplete. Maintain a log of spore test results. Check your state regulations to determine how long you need to keep spore testing records.
Organization for Safety and Asepsis Procedures (OSAP)
Infection Control Guidelines: September, 1997
9. Sterilization Monitoring: The use and functioning of heat sterilizers should be biologically monitored at least weekly, or more often if the practice demands it, with appropriate spore tests. Place the spore strips or vials inside a pouch, bag, pack or cassette, and include this package as part of the normal load through a normal sterilizer cycle. Always use a control spore strip or vial (not heat processed but otherwise treated identically to the test strips or vials) with each spore test performed. Additionally, chemical indicators should be used on the inside of each package during every sterilizer load. Accurate records of sterilization monitoring must be maintained. A chemical indicator from inside each pack may be initialed and dated for each day of patient care and kept in a file. The weekly spore test for each heat sterilization unit may be kept in the same file. Biologically monitor whenever there is a change in packaging, following equipment repair; retest after failure and when training new employees.
Association for the Advancement of Medical Instrumentation (AAMI)
AAMI: Steam Sterilization and Sterility Assurance, 7.5.4 Test Frequency.
"Biological indicators must be used no less than weekly for each sterilizer and, preferably, should be used for each load. More frequent testing should be carried out on an as needed basis (I.E., after major sterilizer repairs, when evaluating sterilization of new products, when implantable or intravascular materials are sterilized, etc.)".
Association of Perioperative Registered Nurses (AORN)
Recommended Practices, Sterilization & Disinfection, 1987.
"For routine monitoring should be used weekly, and as needed; each load of implantables."
VA Manual G1, MP-2, 1985 and MP-2, Sub-chapter E, Change 159, June 22, 1983.
"Must be monitored no less than weekly, each load of implantables or intravascular materials, following major sterilizer repairs, new products or packaging material."
Today, more than ever, you need reliable and easy to use products from a trusted partner who understands your sterilization needs. The Midmark M9 UltraClave® Automatic Sterilizer was specifically designed and engineered to meet those needs. The intuitive display and simple prompts help you easily select the cycle you need... whether it is for unwrapped items, pouches, packs or handpieces. Once the sterilization process is complete, the door conveniently opens automatically and quietly to dissipate the steam and provide fast and efficient drying time of your instruments.
Create peace of mind by making the healthcare market’s leading sterilizer... the Midmark M9 UltraClave... your preferred office choice.
The LCD display indicates cycle selected, cycle temperature and exposure time. When the cycle enters sterilization mode and dry mode, the remaining cycle time is displayed as well as temperature and pressure.
Once the sterilization is complete, the door opens automatically and quietly to dissipate steam and dry your instruments. You’ll have dry, sterile instruments every time.
If the door is not closed completely or the reservoir water level is low, the LCD display will provide the appropriate message. In either case, sterilization can’t continue until you’ve attended to the unit.
For ease of draining and filling, the Midmark M9’s reservoir fill port and drain tube is in the front of the unit, not on top or in back.
The Midmark M9 printer accessory provides a permanent record of cycles, times, temperatures and pressures during a cycle.
Programmable controls allow for creation of different cycle parameters for special sterilization needs. Programmable buttons allow you to change the following: Time (3 to 90 minutes), Temperature (230 to 275˚F), Dry Time (0 to 60 minutes), or Vent (slow or fast). The #1 and #2 buttons allow you to store the change if desired.
Four pre-programmed sterilization cycle controls: Unwrapped (132º C or 270º F for 3 minutes), Pouched (132º C or 270º F for 5 minutes), Packs (121º C or 250º F for 30 minutes), Handpiece (unwrapped and pouched) (132˚ C or 270˚ F for 6 minutes).
Overall length w/plug: 20.13" (51 cm)
Overall width: 15.3" (38.9 cm)
Overall height w/printer: 15.8" (40.1 cm)
15.3" x 20.38" (38.9 cm x 51.8 cm)
3.5 gal. usable volume (13.4 liters)
Two large – 7 5/16" W x 12" L x 7/8" D (18.6 cm x 30.5 cm x 2.2 cm)
Two small – 5 5/8" W x 12" L x 7/8" D (14.3 cm x 30.5 cm x 2.2 cm)
Unit weight: 73 lbs. (33.1 kg)
Water reservoir capacity: 1.1 gal. (4.1 liters)
115 VAC, 50/60 Hz, 15 AMPS Single Phase
115 VAC has 1425-watt tubular immersion heater
230 VAC, 50/60 Hz, 10 AMPS Single Phase
230 VAC has 1500-watt tubular immersion heater
CAN/CSA C22.2 No. 1010.2-041 96
A separate (dedicated) circuit is recommended for this sterilizer
Meets the requirements of ASME Boiler and Pressure Vessel Code