Compact heated make up air for restaurant exhaust hoods

UpUp


Subject: Compact heated make up air for restaurant exhaust hoods
F76 Low CFM Direct Fired Heater.
Supply Fan handles 1500 CFM @ 0.200" wc. Fan runs at 2113 RPM.
Supply Motor: 1.500 HP, 1 Phase 230 V, 10.2 FLA, ODP (Open Drip Proof)
Down Discharge - Air Flow Right -> Left
- Screen Intake Hood with EZ Filter.
- Maxitrol 14 • 40-80°F Discharge Temp Control
- Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
Order # 418643 - Compact DF heater
Model 00158OS1BAOF56-40PP, 1.5 HP, 1 Phs, 230 V, 10.2 FLA, ODP (Open Drip Proof)
Direct-fired burner assembly. 275,000 BTU/HR Maximum, 13,000 BTU/HR Minimum. Aluminum. 6" long. Used in size 1 compact & commercial direct-fired heater. Used for both Natural and Propane Gas. Pilot/Flame Rod/Spark Assembly included.
7" forward curved, centrifugal blower. Permanently lubricated ball bearings. Galvanized finish. 400-2000 CFM. 3/4" Shaft. 3600 max. RPM. Used in heated and non-heated supply fans.
Maxitrol 14 • 40-80°F Discharge Temp Control
Screen Intake Hood with EZ Filter.
1x MV EZ Kleen Metal Mesh Filter. 16"x 20"x 2" Used for heater and supply fan intakes. (3412)
* Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size
The Direct Gas Fired Make-Up Air package is designed to deliver tempered make-up air for installations requiring frequent air changes. Units are designed for natural and propane gas applications, and for indoor or outdoor installation.
Direct Gas-Fired Heater, for use in tempering make-up air. Packages are certified to the ANSI Z83.4a-2001/CSA 3.7a-2001 combined safety standard. One size is available with a max BTU rate of 241,290 and 1,800 CFM. Units are designed for natural or propane applications and are rated for indoor/outdoor installations in commercial occupancies. A unique feature is the self-adjusting burner profile plates allowing 2-speed and variable-air-volume applications. The plates ensure proper air velocity and pressure drop across the burner for clean combustion. Spring-loaded profile plates react to the momentum of the fresh air stream, therefore, no motors or actuators are needed to drive them, nor do they need to be manually set to a specific position.
To satisfy a variety of installation requirements, packages are available in a number of configurations which include additions of filtered intake with easy access door, a trunklinethat is used to move the air intake away from the grease laden exhaust air. Screened intakes are used to stop debris from being pulled in to the heater, the screened intake attaches directly to the filtered intake or the trunkline.
Pre-wired, pre-piped controls.
Stainless steel burner with aluminum casting.
120 volt control transformer with single point electrical connection.
Intermittent spark pilot with timed safety lockout.
High temperature limit switch.
(Options listed below are NOT included in this listing)
Remote control panel including summer/winter switch and operating lights.
Freeze Stat with Bypass Timer.
OPERATION & INSTALLATION MANUALS
Comprehensive Supply Fan Information
Operation and Installation Manual (PDF)
The F76 Model has been certified by ITS. This certification mark indicates that the product has been tested to and has met the minimum requirements of a widely recognized (consensus) U.S. and Canadian products safety standard, that the manufacturing site has been audited, and that the applicant has agreed to a program of periodic factory follow-up inspections to verify continued performance.
Model F76 is ETL Listed under file number J20042560-001 and complies with ANSI Z83.4a-2001 Standards and CSA 3.7a-M99 Standards.