EconAir Complete Stainless Steel Kitchen Ventilation System Includes: Hood including make up air plenum, exhaust fan, supply fan, Pre-Piped Full coverage Ansul Fire System, Electrical pre-wire package, Flat roof curbs for fans, Freight Not included. Commercial Kitchen hood with make up air plenum 48'' x 24'' EX - 12' 0" Long Compensating Wall Canopy Hood with a Front Perforated Supply Plenum (PSP) Accessory. w/ 2 Factory installed 10 X 15" Exhaust Riser(s) 1- 430 Stainless Steel Where Exposed 1- Fire Cabinet on Left of Hood 4- FILTER - 16"x 16" Kleen-Gard Aluminum Baffle Filter with Handles, UL Classified 4- FILTER - 16"x 20" Kleen-Gard Aluminum Baffle Filter with Handles, UL Classified 2- SUPPLY RISER - 8"x 36" Supply Riser with Volume Dampers 1- Electrical Package Installation in Utility Cabinet by Plant. 1- ANSUL-3.0/3.0/1.5 Ansul 7.5 gallon Fire System in Utility Cabinet (includes pre-piped hood(s) with detection, tank(s), release mechanism, microswitches and pull station) 1- GAS VALVE - 2" Mechanical Shutoff Valve (Ansul) *Does not include final hook up 1- BDU18 Belt Drive Centrifugal Upblast Exhaust Fan with 18.75" wheel Exhaust Fan handles 3300 CFM @ 1.200" wc. Fan runs at 1166 RPM. Exhaust Motor: 1.500HP, 1 Phase 115 V, ODP (Open Drip Proof) 1- GREASE CUP - Grease Cup for kitchen-duty centrifugal exhaust fans. 1- NSA12 Belt Drive Supply Unit with 12" Blower in Size #2 Supply Fan handles 2640 CFM @ 0.300" wc. Fan runs at 567 RPM. Supply Motor: 0.500HP, 1 Phase 115 V, ODP (Open Drip Proof) Down Discharge - Air Flow Right -> Left 1- Sloped Filtered Intake for Size #2 Standard Untempered Supply Unit. 22" Wide x 29.25" Long x31.5" High. Includes 2" MV EZ Kleen Metal Mesh Filters. 1- Curb CRB26.5x20E On Fan # 1 1- Hinged Base for Curb. Hinge attached to curb. 1- 11111002 120V/1Ph, W/ 1 Exhaust Fan, 1 Supply Fan, Exhaust in Fire *This pre-wire package includes the contactors and switches for the exhaust fan, supply fan, and lights. This option ensures proper installation with a detailed wiring diagram posted in the cabinet. This saves time and money with your electrician. (Freight Not included) Total Delivered Price $5999.00 Please send your zip code for a freight quote Exhaust Only Hood with Optional Front Supply Plenum econ-air, Inc. reserves the right to modify the design, materials, and/or specifications as a result of code requirements or product enhancements resulting from the Company's ongoing research and development. Econ-air, inc. offers a FULLY INTEGRATED PACKAGE, pre-engineered for OPTIMUM PERFORMANCE. The "package" consists of the hood and options to include an integral ETL Listed utility cabinet (as pictured), containing factory pre-wired, ETL Listed electrical controls and a factory pre-piped UL Listed fire suppression system. Other options include ETL Listed exhaust damper, ETL Listed exhaust/supply air fans in a "combination" Roof Top Package or sold separately, and UL Listed direct-fired heated make-up air units. Fire suppression systems include final hookup and inspection. APPLICATION: Exhaust only, low CFM ventilation hood is ETL Listed for use over 450°F, 600°F, and 700°F cooking surface temperatures. An optional rear plenum provides up to 90% make-up air. * Superior exhaust flow rates (Example: A 4' Hood can perform at 600CFM) * UL 710 Listed for use over 450°F, 600°F and 700°F cooking surface temperatures, providing flexibility in designing kitchen ventilation systems. ETL Listed to Canadian safety standards, NSF Listed and built in accordance with NFPA 96. Recognized by ICBO and BOCA . * Front design prohibits condensation and directs grease-laden vapors toward the exhaust filter bank. Polished stainless steel on the interior and exterior of the front enhance aesthetics. * Up to 90% make-up air supplied through optional rear plenum. * Sturdy stainless steel construction with double wall, insulated front panel. * Factory pre-wired lighting to illuminate cooking surface. * Aluminum filters with optional stainless steel or high velocity cartridge filters (Model ECX). * Optional integral 3" air space provided to meet NFPA 96 clearance requirements against a limited combustible wall; optional insulated, NFPA 96 approved air space available for combustible walls. * Optional ETL Listed light and fan control switches flush mounted and pre-wired through electrical chaseway. * Optional ETL Listed exhaust fire damper (Model EX-D) Max. Avg. Cooking SurfaceTemperature (°F)-Cooking Surfaces Max. Supply CFM/Ft.-via Optional Back Supply Plenum 700°F - Mesquite Grills,Charcoal Charbroilers,Gas Conveyor Charbroilers (2 piece island back to back wall hoods) 700°F - Mesquite Grills,Charcoal Charbroilers,Gas Conveyor Charbroilers 600°F - Gas Charbroilers,Electric Charbroilers (2 piece island back to back wall hoods) 600°F - Gas Charbroilers,Electric Charbroilers 450°F - Ovens, Steamers,Kettles, Open-Burner Ranges,Griddles, Fryers (2 piece island back to back wall hoods) 450°F - Ovens, Steamers,Kettles, Open-Burner Ranges,Griddles, Fryers * Exhaust: Based on 1600 FPM * Supply: Based on 800 to 1200 FPM * Available in wall type or two piece back to back island form. * Fabricated of Type 430 stainless steel, #3 or #4 polish, on all exposed surfaces. Optional type 304 stainless steel available. * Double-wall, insulated front increases rigidity and reduces condensation. * Fitted with ETL Classified, aluminum filters, removable for cleaning. Optional stainless steel and ETL Listed high velocity cartridge filters available. (Model ECX) * Grease drain system (1/8" per foot minimum slope) with removable pint cup for easy cleaning. * Pre-punched hanging angles on each end of hood. Additional set provided for hoods longer than 12'. * Optional integral 3" air space provided to meet NFPA 96 clearance requirements against limited combustible wall; optional insulated NFPA 96 approved air space available for combustible walls. * Fitted with UL/ETL Listed, pre-wired, incandescent light fixtures and plastic-coated glass globes to hold up to a standard 100 watt bulb. Recessed incandescent and recessed fluorescent lights optional. * A built-in wiring chase provided for optimal positioning of electrical controls and outlets on the front face of the hood without penetrating capture area or requiring external chaseway. * Optional ETL Listed exhaust fire damper (Model EX-D). * Model EX is ETL Listed for 400°F, 600°F and 700°F cooking surfaces (File MH 14653 without exhaust damper; File MH 14654 with exhaust damper), NSF Listed and built in accordance with NFPA Standard 96. Recognized by ICBO and BOCA. UTILITY CABINET: ETL Listed for integral side mount on the econ-air ventilation hood...fabricated of same material as hood...the cabinet houses factory pre-piped UL Listed fire suppression system* and ETL Listed, pre-wired electrical controls...pre-wire package* contains light switches, lighted fan control switches and internal factory wiring and components (starters, relays, etc.) to reduce field wiring requirements. ETL tests confirm temperatures do not exceed 120F inside the cabinet during fire condition. (120F is the maximum allowed storage temperature for the UL Listed fire suppression system and the ETL Listed Industrial control panel.) (*Dimensional restrictions may apply) REMOVABLE UL LISTED HIGH-VELOCITY CARTRIDGE FILTER: Constructed of stainless steel...uses centrifugal force to remove grease and other particulates...National Institute of Standards and Technology methodology used by an independent agency to evaluate performance...tests indicate 95 percent extraction efficiency. ENCLOSURE PANELS: Constructed of stainless steel...mounting channel factory-welded to hood for field installation of panels over 11" high...under 11", factory-welded and integrally installed into hood front ends...sized to extend from hood top to ceiling, enclosing pipe and hanging parts. END PANELS: Should be used to maximize hood performance and eliminate the effects of cross drafts in kitchen...units constructed of stainless steel and sized according to hood width and cooking equipment. Exposed edges hemmed for safety and rigidity. EXHAUST FIRE DAMPER: ETL Listed...installed in exhaust collar...activated by a ETL Listed, 212°F, 10-lb. minimum rated fusible link. ROOF TOP PACKAGE: Combination ETL Listed exhaust/supply air unit with factory prewired and mounted motors, ETL Listed trunkline and curb vented on exhaust side. Various models perform up to 14,000 CFM exhaust and up to 3 inches static pressure...weatherproofed...galvanized construction... washable mesh filters...exhaust/supply air fans share common roof penetration...internal wiring drops directly through curb, requiring no pitch pockets...exhaust outlets/air intakes spaced to conform to code regulations...automatic reset/thermal overload protection on all single phase motors and on three phase motors if pre-wire assembly is included in package...standard single-point power connections...ETL 705, 762 Listed exhaust fans rated for high grease applications...optional backdraft dampers. SEPARATE FANS: ETL Listed single exhaust fans and supply-air fans and curbs available...same features, construction methods and performance ratings as roof top package above. HEATED MAKE-UP AIR: ETL Listed direct fired gas heated make-up air unit manufactured by econ-air...ETL Listed for natural gas and propane...design integrates the blower and burner into a single package... heavy duty, weather resistant, galvanized steel construction...units available in Roof Top Package or as a stand alone heated make-up air module...several models available to meet almost any performance rating specification. |